SI Set Sampling Rate to System Model VI

System Identification VIs

SI Set Sampling Rate to System Model VI

Owning Palette: Model Management VIs

Installed With: System Identification Toolkit

Applies a sampling rate to a system model. Use the SI Get Sampling Rate from System Model VI to retrieve the sampling rate from a system model.

 Place on the block diagram  Find on the Functions palette
system model contains information about the model structure, nominal or estimated parameters, identification result, and so on.
sampling rate specifies the sampling rate to apply to system model. If system model is a continuous system, set sampling rate to a value less than or equal to 0.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
system model out returns information about the model structure, nominal or estimated parameters, identification result, and so on.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.