NI-TClk Synchronization in a Single PXI Chassis or a Single PC with Homogeneous Triggers

NI-TClk Synchronization

NI-TClk
Synchronization in a Single PXI Chassis or a Single PC with Homogeneous Triggers

If you are synchronizing several instrument sessions with homogeneous triggers in a single PXI chassis or a single PC, then use the VIs or functions listed in the following table.

LabVIEW VI C Function
niTClk Configure For Homogeneous Triggers VI niTClk_ConfigureForHomogeneousTriggers
niTClk Synchronize VI niTClk_Synchronize
niTClk Initiate VI niTClk_Initiate
(optional)
niTClk Is Done VI
or
niTClk Wait Until Done VI
(optional)
niTClk_IsDone
or
niTClk_WaitUntilDone
N/A niTClk_GetExtendedErrorInfo
Note  Before using these NI-TClk VIs or functions, verify that your system is configured as specified in PXI Trigger Lines and RTSI Lines.

Programming Examples