NITCLK_ATTR_SAMPLE_CLOCK_DELAY
Data Type | Access | Coercion | High-Level Functions |
---|---|---|---|
ViReal64 | R/W | None | None |
Description
Specifies the delay, in seconds, to apply to the session sample clock relative to the other synchronized sessions. During synchronization, NI-TClk aligns the sample clocks on the synchronized devices. If you want to delay the sample clocks, set this attribute before calling niTClk_Synchronize.
Values
Between minus one and plus one period of the sample clock.
One sample clock period is equal to (1/sample clock rate). For example, for a session with sample rate of 100 MS/s, you can specify sample clock delays between –10.0 ns and +10.0 ns.
Default Value
0