NI-TClk Export Sync Pulse Output Terminal Property

NI-TClk Synchronization

NI-TClk
Export Sync Pulse Output Terminal Property

Short Name: ExportSyncPulseOutputTerm

Specifies the destination of the Sync Pulse. This property is most often used when synchronizing a multichassis system.

Values

Empty string. Empty string is a valid value, indicating that the signal is not exported.

PXI Devices

"PXI_Trig0" through "PXI_Trig7", PXI_STAR (Slots 3 through 15), and device-specific settings

PCI Devices

"RTSI_0" through "RTSI_7" and device-specific settings

Examples of Device-Specific Settings

  • NI PXI-5122 supports "PFI0" and "PFI1"
  • NI PXI-5421 supports "PFI0", "PFI1", "PFI4", and "PFI5"
  • NI PXI-6551/6552 supports "PFI0", "PFI1", "PFI2", and "PFI3"

Default Value

Empty string

Remarks

The following table lists the characteristics of this property.

Data Type ViString
Permissions R/W
Corresponding Active Channels N/A