White Reference (Volts)
From NI-IMAQ VI
White Reference (Volts)
Gets/sets the white reference level, in volts, of the channel associated with this session. Refer to the following tables for value ranges that are valid for each device.
| Note The white reference level must be greater than the black reference level. |
Values
The following table includes possible values:
| Datatype | Readable | Writable | Device | Range (volts) |
|---|---|---|---|---|
| Always | Configuration | NI 1405 | 0 to 1.26 | |
| Always | Always | NI 1407 (PCI Rev A through E or later) | 0 to 1.26 | |
| Always | Always | NI 1407 (PXI All Revs) | 0 to 1.26 | |
| Always | Configuration | NI 1409 | 0 to 1.4 | |
| Always | Configuration | NI 1410 | 0 to 1.4 | |
| Always | Configuration | NI 1411 (PXI and PCI Rev A) | 0 to 0.08 | |
| Always | Configuration | NI 1411 (PXI and PCI Rev B or later) | 0 to 1.26 |