Returns a copy of an acquired image. IMAQ Copy allows you to copy an image from onboard memory to system memory or from system memory to system memory.

IMAQ Copy

cgenclasstagrefflat.gif

Image In is a reference to an image.

c1di32.gif

Region of Interest specifies a rectangular portion of the image. Region of Interest is defined by an array of four elements [Left, Top, Right, Bottom]. You must set the width [Right-Left] to a multiple of eight. The [Right] and [Bottom] coordinates are exclusive. If Region of Interest is not connected or empty, the current region of interest is captured.

cbool.gif

Immediate? determines if the system returns the image currently being acquired or the last completely acquired image. The default value if FALSE, which causes NI-IMAQ to wait until the current image is completely acquired before returning the image. TRUE returns the next acquired image

cu32.gif

Buffer Index Buffer Number is the number of the acquired buffer to copy into Image In.

ierrcodeclst.gif

error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.

ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

ii32.gif

code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.

istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.

cerrcodeclst.gif

error in (no error) describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.

cbool.gif

status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.

ci32.gif

code code is the number identifying an error or warning. If status is TRUE, code is a non-zero error code. If status is FALSE, code can be zero or a warning code. Use the error handler VIs to look up the meaning of this code and to display the corresponding error message.

cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.

crn.gif

IMAQ Session In identifies the device.

irn.gif

IMAQ Session Out has the same value as IMAQ Session In.

igenclasstagrefflat.gif

Image Out is a reference to the image.