DAQmx Configure TEDS
Associates TEDS information with the physical channel you specify. If you do not specify the filename of a data sheet in the virtual TEDS file input, this VI attempts to find a TEDS sensor connected to the physical channel. This VI temporarily overrides any TEDS configuration for the physical channel that you performed in MAX.
Place on the block diagram. | Find on the Functions palette. |
physical channel is the name of the physical channel you want to configure. A DAQmx physical channel constant or control lists all physical channels on devices and modules installed in the system. You also can wire a string that contains a physical channel name to this input. | |||||||
virtual TEDS file is the path to a Virtual TEDS data sheet that you want to associate with the physical channel. If you do not wire anything to this input, this VI attempts to find a TEDS sensor connected to the physical channel. | |||||||
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
|
|||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
|