AO Series, E Series, and S Series Signal Connections for Counters

NI-DAQmx Device Considerations

AO Series, E Series, and S Series Signal Connections for Counters

The following table lists the default input terminals for various counter measurements. You can use a different PFI line for any of the input terminals, with the exception of the count direction terminal for edge counting. To change the PFI input for a measurement, use the NI-DAQmx channel attributes/properties.

Measurement Ctr0 Ctr1
Count Edges Edges: PFI 8

Count Direction1: port0/line6
Edges: PFI 3

Count Direction1: port0/line7
Pulse Width Measurement PFI 9 PFI 4
Period/Frequency Measurement (Low Frequency with One Counter) PFI 9 PFI 4
Period/Frequency Measurement (High Frequency with Two Counters) PFI 8 PFI 3
Period/Frequency Measurement (Large Range with Two Counters) PFI 8 PFI 3
Semiperiod Measurement PFI 9 PFI 4
1 The count direction terminal must be tristated to use an external signal. Reset the device to ensure the terminal is tristated.

The following table lists the default output terminals for counter output. You must use the default output terminal, with the exception that for Ctr0, you can select a RTSI line.

Ctr0 Ctr1
CTR 0 OUT CTR 1 OUT