DrawingMaster and Electrostatic Configuration

AutoCAD

 
DrawingMaster and Electrostatic Configuration
 
 
 

Specifies configurations for configure DrawingMaster and Electrostatic plotters.

To configure DrawingMaster and Electrostatic plotters, you need an RS-232 terminal. Configure the terminal for 19,200 baud, 8 data bits, 1 stop bit and no parity. With an RS-232 terminal, you can configure your plotter for either a parallel or a serial connection to AutoCAD. Generally, a parallel connection will produce faster plots. Use a standard Centronics parallel cable.

DrawingMaster and Electrostatic parallel port configuration

Parameter Setting
Input monitor dump NO
I/F type CET
Print N
Dead job time-out (SEC) 90
Time-out action FORCE
Plot command language 907
Steps per inch 400
Beginning of record sync character $16
Number of sync characters 2
End of record character $0D
Checksum Y

DrawingMaster and Electrostatic serial port configuration

Parameter Setting
Input monitor dump NO
Baud rate 9600
Character framing (bits, parity, stop bits) 7,E,1
Host to plotter CDCL protocol XONXOFF
Plotter to host CDCL protocol XONXOFF
Dead job time-out (SEC) 90
Time-out action FORCE
Plot command language 907
Steps per inch 400
Beginning of record sync character $16
Number of sync characters 2
End of record character $0D
Checksum Y

DrawingMaster and Electrostatic plotters communicate with AutoCAD at 9600 baud, 7 data bits, 1 stop bit, and even parity, when an RS232 serial connection is used.