To achieve the maximum of sensitivity the CTMU charge delay must be set to charge the sensor to the voltage level about 75% of AVdd . This optimal delay value can be calculated with MTouchDebugDelay(…) function. The calculated optimal value should be passed for initialization to MTouchSetSensor(…).