Logging
Datalogging Menu
Datalogging
Toolbar
Connect To Ecu:
Click
"Datalog "->"Connect"
Click Connect Icon(first from left) on the tool
bar
Note: If auto-scan datalogging is enabled in setting it takes a little
longer to connect to the ecu.
Record datalog:
The datalog will
be recored in a temp log file(eCtune diretory ~tmp.elf).
If eCtune ever crashes you can open that file to review
your last log.
Click "Datalog" -> "Record"
Click Record icon(second from left) on datalog toolbar
Save datalog:
Click
"Datalog" -> "Save"
Click Save icon on the datalog
toolbar
Datalogging Options(Settings
menu):
Sampling rate: Set how fast your display will be updated. To
much data to fast makes your screen unreadable
Load datalog after recording:
If this is enabled after recording the temporary log file is loaded after
recording stopped. You view graphs to see where something went wrong.
Add
data and time to log file: This will add the time and date to filename when
saving a log file
Record on connection: This will start recording as soons as
a connection to the ecu is made
Play datalog on load: This will start playing
the datalog when opened
Shortcuts:
Connect to ecu:
CTRL + ALT + D
Record: CTRL + ALT + R