ViStatus niSwitch_CheckAttributeViString (ViSession vi, ViConstString channelName, ViAttr attributeID, ViConstString attributeValue);

Purpose

Checks the validity of a value you specify for a ViString attribute.

Parameters

Name Type Description
vi ViSession A particular NI-SWITCH session established with niSwitch_InitWithTopology, niSwitch_InitWithOptions, or niSwitch_init and used for all subsequent NI-SWITCH calls.

channelName ViConstString Some attributes are unique for each channel. For these, pass the name of the channel. Other attributes are unique for each switch. Pass VI_NULL or an empty string for this parameter. The default value is an empty string.
attributeID ViAttr Pass the ID of an attribute. From the function panel window in LabWindows/CVI, you can use this control as follows. Click on the control or press <ENTER>, <spacebar>, or <ctrl-down arrow>, to display a dialog box containing a hierarchical list of the available attributes. Attributes whose value cannot be set are dim. Help text is shown for each attribute. Select an attribute by double-clicking on it or by selecting it and then pressing <ENTER>. Read-only attributes appear dim in the list box. If you select a read-only attribute, an error message appears. A ring control at the top of the dialog box allows you to see all IVI attributes or only the attributes of the ViString type. If you choose to see all IVI attributes, the data types appear to the right of the attribute names in the list box. The data types that are not consistent with this function are dim. If you select an attribute data type that is dim, LabWindows/CVI transfers you to the function panel for the corresponding function that is consistent with the data type. If you want to enter a variable name, press <CTRL-T> to change this ring control to a manual input box. If the attribute in this ring control has constants as valid values, you can view the constants by moving to the Attribute Value control and pressing <ENTER>.

attributeValue ViConstString Pass the value which you want to verify as a valid value for the attribute. From the function panel window in LabWindows/CVI, you can use this control as follows. If the attribute currently showing in the Attribute ID ring control has constants as valid values, you can view a list of the constants by pressing <ENTER> on this control. Select a value by double-clicking on it or by selecting it and then pressing <ENTER>.
Note  Some of the values might not be valid depending on the current settings of the instrument session.