IMAQdx Reset Ethernet Camera Address VI
Installed With: NI Vision Acquisition SoftwareReset Ethernet camera address. Use this function to reset Ethernet cameras on the network with a local subnet. This function will be blocked and will return when the reset is complete or after the specified timeout.
Timeout (1000 ms) specifies the time, in milliseconds, allowed for the Ethernet camera reset to complete. The default timeout is 1000 ms. |
|||||||
Session In specifies the name of the camera you wish to reset. The default value is cam0. |
|||||||
Camera Address (0.0.0.0) specifies the new address, subnet and gateway for the Ethernet camera to reset to. Specify a valid address to configure the camera's new address. Specify an empty address to merely reset the camera Ethernet address. The default address is 0.0.0.0. |
|||||||
error in describes the error status before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node. Explain Error (or Explain Warning) gives more information about the error displayed.
|
|||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, error out describes the error status that this VI produces. The pop-up option Explain Error (or Explain Warning) gives more information about the error displayed.
|