CNiIviScopeTrigger::Holdoff

Measurement Studio IVI

Class
CNiIviScopeTrigger::
Holdoff
Base ClassesData ItemsFunctionsGo to hierarchy chart    Prev page: GlitchNext page: Level    
Public Data Item Declared in:
NiIviScope.h

'Declaration' icon -- Shortcut to top of page. Declaration

double Holdoff;

'Description' icon -- Shortcut to top of page. Description

Specifies the length of time in seconds that the oscilloscope waits after it detects a trigger until it enables the trigger subsystem to detect another trigger.

This property affects instrument operation only when the oscilloscope requires multiple acquisitions to build a complete waveform. The oscilloscope requires multiple waveform acquisitions when it uses equivalent-time sampling or when you set the Acquisition.Type property to CNiIviScope::Envelope or CNiIviScope::Average.