Set Scan Engine Period VI
Owning Palette: NI Scan Engine VIs
Installed With: RT Module
Sets the scan period of the NI Scan Engine on the target.
Place on the block diagram | Find on the Functions palette |
target address specifies the IP address or DNS name of the target. | |||||||
scan period (uSec) specifies the period for the scan engine running on the target. | |||||||
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Use exception control to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
Set Scan Engine Period Details
Changing the scan period while the scan engine is running can take a significant amount of time, and might cause the scan engine to run late, resulting in a major fault. If changing the scan period results in a fault, you can safely clear the fault after the new scan period takes effect.
Note If the target includes an expansion I/O driver, you can set the scan period only when the NI Scan Engine is in Configuration Mode. You can use the Set Scan Engine Mode VI before this VI to put the NI Scan Engine on the target into Configuration Mode. |
Example
Refer to the Scan Engine.lvproj in the labview\examples\scanengine directory for an example of using the Set Scan Engine Period VI.