IMAQ IO Read Shutdown States

NI-IMAQ I/O Control

IMAQ IO Read Shutdown States

Use IMAQ IO Read Shutdown States to review the shutdown settings for the TTL and ISO outputs on the NI-IMAQ I/O device.

Resource In is a string input that represents the name of the device to read shutdown values from. You can select the device name from the list of devices on your machine, or you can type the name and IP address of the device you want to target.

In the list of device names, the names are the VISA name for the device, which is defined in Measurement & Automation Explorer (MAX). For example, the device name might be similar to RIO#::INSTR, where # represents the number of the RIO device, depending on how many RIO devices are installed in the system.

error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE if an error occurred before this VI or function ran or FALSE to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
TTL Outputs
Out 0—Valid values are Drive High, Drive Low, and 3-State.
Out 1—Valid values are Drive High, Drive Low, and 3-State.
Out 2—Valid values are Drive High, Drive Low, and 3-State.
Out 3—Valid values are Drive High, Drive Low, and 3-State.
Out 4—Valid values are Drive High, Drive Low, and 3-State.
Out 5—Valid values are Drive High, Drive Low, and 3-State.
Out 7—Valid values are Drive High, Drive Low, and 3-State.
TRIG 1—Valid values are Drive High, Drive Low, and 3-State.
TRIG 2—Valid values are Drive High, Drive Low, and 3-State.
Isolated Outputs
Out 0—Valid values are Off and On.
Out 1—Valid values are Off and On.
Out 2—Valid values are Off and On.
Out 3—Valid values are Off and On.
Resource Out is a string output that represents the name of the device.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out indicator on the front panel and select Explain Error from the shortcut menu for more information about the error.
status is TRUE if an error occurred or FALSE to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.