Voltage Level Autorange

NI DC Power Properties

DC Voltage:Voltage Level Autorange

Short Name: Voltage Level Autorange

Specifies whether or not NI-DCPower automatically selects the voltage level range based on the desired voltage level for the specified channel(s).

If this property is set to On, NI-DCPower ignores any changes you make to the Voltage Level Range property. If you change the Voltage Level Autorange property from On to Off, NI-DCPower remembers the last value that the Voltage Level Range property was set to (or the default value if it was never set) and uses that value as the voltage level range.

Read the Voltage Level Range property to find out which range NI-DCPower automatically selects.

The Voltage Level Autorange property is applicable only if the Output Function property is set to DC Voltage.

Defined Values:

OnNI-DCPower automatically selects the voltage level range.
OffNI-DCPower does not automatically select the voltage level range.

Default Value: Off

Remarks

The following table lists the characteristics of this property.

Data Type ViInt32
Permissions R/W
Channel Based Yes
High-Level VI None