MB Slave Write Input Registers (poly).vi
Writes multiple input registers to the slave memory tables.
Starting Address is the address location of the first input register to write. This address is sometimes referred to as offset. | |||||||
Input Registers to write. The array length represents the quantity. Note: Only the slave can write input registers. | |||||||
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, the VI or function runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| |||||||
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|