Serial Quick Connect Options
From SecureCRT
A data path or circuit between two computers over a phone line, network cable, or other means.
A session is a set of options that are assigned to a connection to a remote machine. These settings and options are saved under a session name and allow the user to have different preferences for different hosts.
When Serial is selected as the Protocol
in the Quick Connect
dialog, the connection
options are as follows:
Port
The serial port (COM1, COM2, etc.) used by the session.
Baud rate
Select the baud rate for the device. The default value
is 38400. The baud rate can be changed from the Session Options/Connect/Serial dialog while
a session is connected.
Data bits
The number of communication data bits. The default value
is 8.
Parity
Choose the parity setting supported by the connected
device. The default setting is None.
Stop bits
The number of stop bits sent after each character. The
default value is 1.
DTR/DSR
Select this option to use the DTR/DSR (data-terminal-ready/data-set-ready) signals with the connected device. By default, this is not selected.
RTS/CTS
Select this option to use RTS/CTS (request-to-send/clear-to-send) hardware flow control. By default, this option is selected.
XON/XOFF
Select this option to use XON/XOFF software flow control. By default, this option is not selected.