Signaling Hold Time

Radioddity GD-77 / CPS 2.0.5

Signaling Hold Time

Sets the amount of time that the radio waits on an analog scan list channel when a carrier signal of sufficient amplitude is detected on the channel. This pause allows the radio time to decode the analog system signaling data. If the decoded information is incorrect, the radio reverts to scan.

Range
Max6375
Min50
Step25
Note
  • This function must be equal to or greater than the sum of the time required for the radio to transmit signaling packets and the signaling system lead time for that channel.