niScope Get Session Reference

NI-SCOPE LabVIEW

niScope Get Session Reference

Extracts a session that can be passed to NI-TClk VIs. Session References are of generic type, which means that the corresponding wires are blue-green, unlike the wires for regular instrument driver sessions.

instrument handle identifies a particular instrument session.
error in describes error conditions that occur before this VI or function runs.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a negative error code. If status is FALSE, code is 0 or a warning code.
source identifies where an error occurred. The source string includes the name of the VI that produced the error, what inputs are in error, and how to eliminate the error.
instrument handle out has the same value as the instrument handle.
session reference references the device session that can be passed to NI-TClk VIs.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source identifies where and why an error occurred. The source string includes the name of the VI that produced the error, what inputs are in error, and how to eliminate the error.