Pneumatic_Sensor_Loop.vi

LabView Pneumatic Sensor Loop

Pneumatic_Sensor_Loop.vi

Help by FRC Team 836 - The RoboBees

This VI configures the sensors for the pneumatics.

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

ccclst

Cluster

    cqueuern

    Status Queue

    cfiforn

    Status Loop

    cenum

    Value

ccclst

Solenoid Configuration

    cnclst

    Normal Timing

      cdbl

      Forward

      cdbl

      Reverse

    cenum

    Feedback Forward

    cenum

    Feedback Reverse

    cnclst

    Analog Thresholds

      cdbl

      Forward

      cdbl

      Reverse

    cnclst

    Timeout

      cdbl

      Forward

      cdbl

      Reverse

ccclst

AIDeviceRef

    cerrcodeclst

    DevStatus

      cbool

      status

      status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      ci32

      code

      code is the error or warning code.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      cstr

      source

      source describes the origin of the error or warning.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

    cenum

    Analog Channel

ccclst

DigitalInputDevRef

    cerrcodeclst

    DevStatus

    error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

    Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      cbool

      status

      status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      ci32

      code

      code is the error or warning code.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      cstr

      source

      source describes the origin of the error or warning.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

    cenum

    DIO Channel

ci32

Priority

ci64

Period

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

Pneumatic_Sensor_Loop.vi

FPGA_AIChannel.ctl

FPGA_AIChannel.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\SystemInterfaces\AI\FPGA_AIChannel.ctl

WPI_AnalogChannelDevRef.ctl

WPI_AnalogChannelDevRef.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\AnalogChannel\WPI_AnalogChannelDevRef.ctl

WPI_AnalogChannelGetAverageVoltage.vi

WPI_AnalogChannelGetAverageVoltage.vi

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\AnalogChannel\WPI_AnalogChannelGetAverageVoltage.vi

FPGA_DIOChannel.ctl

FPGA_DIOChannel.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\SystemInterfaces\DIO\FPGA_DIOChannel.ctl

WPI_DigitalInputGetValue.vi

WPI_DigitalInputGetValue.vi

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\DigitalInput\WPI_DigitalInputGetValue.vi

WPI_DigitalInputDevRef.ctl

WPI_DigitalInputDevRef.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\DigitalInput\WPI_DigitalInputDevRef.ctl

Stable.vi

Stable.vi

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Logic\Stable.vi

Solenoid_Configure.ctl

Solenoid_Configure.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Solenoid_Configure.ctl

Feedback_Method.ctl

Feedback_Method.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Feedback_Method.ctl

Pneumatics_Configuration.ctl

Pneumatics_Configuration.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Pneumatics_Configuration.ctl

WPI_SolenoidValue.ctl

WPI_SolenoidValue.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\Solenoid\WPI_SolenoidValue.ctl

Pneumatic_Sensor_Loop.ctl

Pneumatic_Sensor_Loop.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Pneumatic_Sensor_Loop.ctl

Pneumatics_Status.ctl

Pneumatics_Status.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Pneumatics_Status.ctl

"Pneumatic_Sensor_Loop.vi History"

Current Revision: 7


Position in Hierarchy

Pneumatic_Sensor_Loop.vi


Iconified Cluster Constants