This VI initializes the pneumatic control & sensor loops.

Pneumatic_Control_Initialize.vi

Pneumatic_Control_Initialize.vi

ccclst

SolenoidDevRef

    cerrcodeclst

    DevStatus

    error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

    Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      cbool

      status

      status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      ci32

      code

      code is the error or warning code.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      cstr

      source

      source describes the origin of the error or warning.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

    cu8

    Pneumatics Control Module

    cenum

    Forward Solenoid Channel

    cenum

    Reverse Solenoid Channel

cbool

Forward?

cstr

name (unnamed)

icclst

Sense Loop

    iqueuern

    Status Queue

    ififorn

    Status Loop

    ienum

    Value

icclst

Control Loop

    inotern

    Control Notifier

    ienum

    Initial Position

    icclst

    SolenoidDevRef

      ierrcodeclst

      DevStatus

      error in can accept error information wired from VIs previously called. Use this information to decide if any functionality should be bypassed in the event of errors from other VIs.

      Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

        ibool

        status

        status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

        Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

        ii32

        code

        code is the error or warning code.

        Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

        istr

        source

        source describes the origin of the error or warning.

        Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error.

      iu8

      Pneumatics Control Module

      ienum

      Forward Solenoid Channel

      ienum

      Reverse Solenoid Channel

    ififorn

    Status Loop

Pneumatic_Control_Initialize.vi

WPI_SolenoidSetEnum.vi

WPI_SolenoidSetEnum.vi

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\Solenoid\WPI_SolenoidSetEnum.vi

WPI_SolenoidChannel.ctl

WPI_SolenoidChannel.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\Solenoid\WPI_SolenoidChannel.ctl

WPI_SolenoidDevRef.ctl

WPI_SolenoidDevRef.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\Solenoid\WPI_SolenoidDevRef.ctl

WPI_SolenoidValue.ctl

WPI_SolenoidValue.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\Solenoid\WPI_SolenoidValue.ctl

WPI_SolenoidSet.vi

WPI_SolenoidSet.vi

C:\Program Files (x86)\National Instruments\LabVIEW 2015\vi.lib\Rock Robotics\WPI\Solenoid\WPI_SolenoidSet.vi

Solenoid_Control_Loop.ctl

Solenoid_Control_Loop.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Solenoid_Control_Loop.ctl

Pneumatics_Position.ctl

Pneumatics_Position.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Pneumatics_Position.ctl

Pneumatics_Command.ctl

Pneumatics_Command.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Pneumatics_Command.ctl

Pneumatic_Sensor_Loop.ctl

Pneumatic_Sensor_Loop.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Pneumatic_Sensor_Loop.ctl

Pneumatics_Status.ctl

Pneumatics_Status.ctl

C:\Program Files (x86)\National Instruments\LabVIEW 2015\user.lib\836-Library\Pneumatics\Support_Code\Pneumatics_Status.ctl

"Pneumatic_Control_Initialize.vi History"

Current Revision: 7


Position in Hierarchy

Pneumatic_Control_Initialize.vi


Iconified Cluster Constants