3-way flow control valve
With sufficient pressure, the preset flow rate is kept constant in the direction of the arrow. The surplus hydraulic fluid is drained at connection T using a pressure compensator. The inlet pressure pA is load dependent, i.e it changes with the outlet pressure pB. Therefore a parallel circuit of several 3-way flow control valves is not possible. In this case, the inlet pressures would be defined by the valve with the lowest inlet pressure. Compared to the 2-way flow control valve, the 3-way flow control valve is admittedly more efficient in its energy consumption.
The hydraulic resistance relates to the completely closed pressure compensator.
Adjustable parameters
Nominal flow: 0.01 ... 500 l/min (1)
Hydraulic resistance: 1e-7 ... 100 MPa*min2/l2 (0.01)