Closing pressure compensator

FluidSIM 4 Hydraulics

Previous Next

Closing pressure compensator

         

The pressure compensator represents a pressure dependent hydraulic resistance. The pressure compensator closes when the pressure difference X-Y exceeds the nominal pressure. A pressure regulating valve is implemented by the combination of connections A and X. The pressure balance is also a component of 2-way flow control valves.

The nominal pressure setting of the real components is component dependent and cannot be changed.

The hydraulic resistance relates to the completely opened valve.

Adjustable parameters

          Nominal pressure:         0.01 ... 40 MPa    (1)

     Hydraulic resistance:         1e-7 ... 100 MPa*min2/l2 (0.01)

Related Topics

Closing pressure compensator, adjustable

2-way pressure reducing valve

2-way flow control valve

Opening pressure compensator

[146]  2-way flow control valve (1)


Previous Next