Check valve with pilot control, spring loaded
If the input pressure is higher than the output and nominal pressure, the check valve opens. Otherwise it is shut. In addition, the check valve can be opened via a control line, allowing flow in both directions.
Adjustable parameters
Nominal pressure: 0.001 ... 40 MPa (0.1)
Area ratio: 1 ... 10 (5)
Hydraulic resistance: 1e-7 ... 100 MPa*min2/l2 (0.01)
Related Topics
Check valve with pilot control
Pilot to close check valve, spring loaded
[131] Delockable non-return valve (1)
[134] Circuit diagram: Delockable non-return valve
[135] Delockable non-return valve