[32] Pressure transfer (2)

FluidSIM 4 Hydraulics

Previous Next

[32 Pressure transfer (2)

A pressure-transfer effect also occurs in conventional double acting cylinders with single piston rod.

 

This effect also causes problems in hydraulics. If, for example, an exhaust flow control is fitted to a differential cylinder for the advance stroke, a pressure- intensification effect results in the piston-rod chamber.