MarkerPSAT

M9370A / M9371A / M9372A / M9374A / M9375A

Calculate:Marker:PSaturation Commands


Initiates a Power Saturation marker search and reads the results.

CALCulate:MARKer:PSATuration

BACKoff

COMPression

     | MAXimum?

     | SATuration?

GAIN?

     | LINear?

     | MAXimum?

PIN?

     | MAXimum?

POUT?

     | MAXimum?

Click on a keyword to view the command details.

See Also

Critical Note: CALCulate commands act on the selected measurement. You can select one measurement for each channel using Calc:Par:MNUM or Calc:Par:Select. Learn more.


CALCulate<cnum>:MARKer:PSATuration:BACKoff <num>

(Read-Write)  Turns on and sets markers 1, 2, and 3 to calculate various Power Saturation parameters.

The <num> parameter sets and reads the back-off value for a Power Saturation marker search.

To turn off the Power Saturation markers, either turn them off individually or turn them All Off.

To search a User Range with the PSAT search, first activate marker 1 and set the desired User Range. Then send the CALC:MARK:PSAT:BACK command. The user range used with the PSAT search only applies to marker 1 searching for the linear gain value. The other markers may fall outside the user range.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

<num>

Backoff value. Choose any number between :-500 and 500

Examples

CALC:MARK:PSAT:BACK 3
calculate2:marker:psaturation:backoff 10

Query Syntax

CALCulate<cnum>:MARKer:PSATuration:BACKoff?

Return Type

Numeric

Default

0


CALCulate<cnum>:MARKer:PSATuration:COMPression:MAXimum?

(Read-only) Reads the compression maximum value from a PSAT marker search.

Comp Max = Gain Max - Gain Linear

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:COMP:MAX?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:COMPression:SATuration?

(Read-only) Reads the compression saturation value from a PSAT marker search.

Comp Sat = Gain Sat - Gain Linear

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:COMP:SAT?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:GAIN?

(Read-only) Reads the saturation gain value from a PSAT marker search.

Gain Sat = Psat Out - Psat In

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:GAIN?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:GAIN:LINear?

(Read-only) Reads the linear gain value from a PSAT marker search.

Gain Linear = Marker 1 - Y-axis value MINUS X-axis value.

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:GAIN:LIN?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:GAIN:MAXimum?

(Read-only) Reads the maximum gain value from a PSAT marker search.

Gain Max = PMax Out - PMax In

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:GAIN:MAX?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:PIN?

(Read-only) Reads the power saturation input value from a PSAT marker search.

Psat In = Marker 2 X-axis value

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:PIN?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:PIN:MAXimum?

(Read-only) Reads the maximum input power from a PSAT marker search.

PMax In = Marker 3 X-axis value

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:PIN:MAX?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:POUT?

(Read-only) Reads the back-off output power from a PSAT marker search.

PSat Out = Marker 2 Y-axis value

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:POUT?

Default

Not applicable


CALCulate<cnum>:MARKer:PSATuration:POUT:MAXimum?

(Read-only) Reads the back-off output power from a PSAT marker search.

PMaxOut = Marker 3 Y-axis value

Use CALC:MARK:PSAT:BACK to initiate a PSAT search.

See Critical Note

Parameters

 

<cnum>

Channel number of the measurement. There must be a selected measurement on that channel. If unspecified, <cnum> is set to 1.

Examples

CALC:MARK:PSAT:POUT:MAX?

Default

Not applicable