Modbus
Notes:
/ indicates the protocal or protocal is uncertain.
Product
Series |
Device
Type |
Protocol Highest
Ver. |
RealTime |
EventLog |
Waveform |
DataLog |
Time
Sync |
Control |
Comm.
interface |
Module |
Device
Classification |
Driver
Type |
Notes |
Sepam |
S20 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
T20 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
M20 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
B20 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
B21 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
B22 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
S40 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
S41 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
S42 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
T40 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
T42 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
M41 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
G40 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
Sepam |
S80 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Protection
Relay |
R-C10-MOD-C |
Need ACE959 |
MC |
MC08 |
/ |
■ |
× |
× |
× |
× |
■ |
RS485 |
DrvSchneider |
Monitoring and Control
Device |
R-C10-MOD-A |
|
MC |
MC09 |
/ |
■ |
× |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
MC |
MC18 |
/ |
■ |
× |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
MT |
MT-A |
/ |
■ |
■ |
× |
× |
■ |
■ |
RS485 |
DrvSchneider |
Monitoring and Control
Device |
R-C10-MOD-B |
|
MT |
MT-P |
/ |
■ |
■ |
× |
× |
■ |
■ |
RS485 |
DrvSchneider |
Monitoring and Control
Device |
R-C10-MOD-B |
|
PM |
PM200 |
/ |
■ |
× |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
PM |
PM210 |
/ |
■ |
× |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
PM |
PM500 |
/ |
■ |
× |
× |
× |
× |
■ |
RS485 |
DrvSchneider |
Monitoring and Control
Device |
R-C10-MOD-A |
|
PM |
PM5350 |
/ |
■ |
× |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
PM |
PM710 |
/ |
■ |
□ |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
PM |
PM750 |
/ |
■ |
□ |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
PM |
PM810 |
/ |
■ |
■ |
× |
× |
■ |
■ |
RS485 |
DrvSchneider |
Monitoring and Control
Device |
R-C10-MOD-B |
|
PM |
PM850 |
/ |
■ |
■ |
■ |
× |
■ |
■ |
RS485 |
DrvSchneider |
Monitoring and Control
Device |
R-C10-MOD-C |
|
CM |
CM4000 |
/ |
■ |
■ |
■ |
□ |
■ |
■ |
RS485 |
DrvSchneider |
Power Quality
Meter |
R-C10-MOD-C |
|
CM |
CM4000 |
/ |
■ |
■ |
■ |
□ |
■ |
■ |
Ethernet |
DrvSchneider |
Power Quality
Meter |
R-C10-MOD-C |
|
NRC |
NRC |
/ |
■ |
× |
× |
× |
× |
× |
RS485 |
DrvSchneider |
Meter |
R-C10-MOD-A |
|
ION |
6200 |
/ |
■ |
× |
× |
× |
× |
■ |
RS485 |
DrvModbus |
Monitoring and Control
Device |
R-C10-MOD-A |
|