Front Panel:Run-Time Position:Minimized Method
Short Name: FP.Run-Time Position.Minimized
Installed With: Base Package
Class: VI Methods
Sets a VI to minimize its front panel every time the VI runs.
Parameters
| Name | Required | Description |
|---|---|---|
| Monitor | No | Specifies the monitor on which the front panel window appears, if you have multiple monitors. The value 0 is the primary monitor and is the default value. If you specify a value other than 0, the VI runs on that monitor. If you specify a monitor number greater than the number of monitors on the system, or if you specify a negative number, LabVIEW returns an error. The monitor number corresponds to the video card you plug the monitor in to. |
Remarks
The following table lists the characteristics of this method.
| Available in Run-Time Engine and Real-Time Operating System | Yes (Read/Write) |
| Settable when the VI is running | Yes |
| Loads the front panel into memory | No |
| Need to authenticate before use | No |
| Loads the block diagram into memory | No |
| Remote access disallowed | No |
| Must wait until user interface is idle | No |
| Available with control VIs | Yes |
| Available with global VIs | Yes |
| Available with strict type definitions | No |
| Available with polymorphic VIs | Yes |