Counter Input >> Period >> Measurement Specifications >> Method

NI-DAQmx C Properties

Counter Input >> Period >> Measurement Specifications >> Method

Data Type: int32
Description: Specifies the method to use to measure the period of the signal.

Valid values

DAQmx_Val_LowFreq1Ctr 10105 Use one counter that uses a constant timebase to measure the input signal.
DAQmx_Val_HighFreq2Ctr 10157 Use two counters, one of which counts pulses of the signal to measure during the specified measurement time.
DAQmx_Val_LargeRng2Ctr 10205 Use one counter to divide the frequency of the input signal to create a lower-frequency signal that the second counter can more easily measure.


You can get/set/reset this property using:
  DAQmxGetCIPeriodMeasMeth
  DAQmxSetCIPeriodMeasMeth
  DAQmxResetCIPeriodMeasMeth