More >> AI Convert >> Timebase >> Source

NI-DAQmx C Properties

More >> AI Convert >> Timebase >> Source

Data Type: int32
Description: Specifies the terminal of the signal to use as the AI Convert Clock Timebase.

Valid values

DAQmx_Val_SameAsSampTimebase 10284 Use the same source as Sample Clock timebase.
DAQmx_Val_SameAsMasterTimebase 10282 Use the same source as the Master Timebase.
DAQmx_Val_20MHzTimebase 12537 Use the onboard 20MHz timebase.
DAQmx_Val_80MHzTimebase 14636 Use the onboard 80MHz timebase.


You can get/set/reset this property using:
  DAQmxGetAIConvTimebaseSrc
  DAQmxSetAIConvTimebaseSrc
  DAQmxResetAIConvTimebaseSrc
  DAQmxGetAIConvTimebaseSrcEx
  DAQmxSetAIConvTimebaseSrcEx
  DAQmxResetAIConvTimebaseSrcEx