Analog Input >> Frequency >> Voltage >> Hysteresis

NI-DAQmx C Properties

Analog Input >> Frequency >> Voltage >> Hysteresis

Data Type: float64
Description: Specifies in volts a window below Threshold Level. The input voltage must pass below Threshold Level minus this value before NI-DAQmx recognizes a waveform repetition at Threshold Level. Hysteresis can improve the measurement accuracy when the signal contains noise or jitter.

You can get/set/reset this property using:
  DAQmxGetAIFreqHyst
  DAQmxSetAIFreqHyst
  DAQmxResetAIFreqHyst