DAQmxAdjust1141Cal

NI-DAQmx C Functions

DAQmxAdjust1141Cal

int32 DAQmxAdjust1141Cal (uInt32 calHandle, float64 refVoltage, float64 measOutput);

Purpose

Adjusts the external calibration constants for the SCXI-1141 module. You must supply a known voltage to the device and specify that voltage with refVoltage.

Parameters

Input
Name Type Description
calHandle uInt32 A reference to the calibration session that you created using the DAQmxInitExtCal function.
refVoltage float64 The known voltage, in volts, to use as a reference for calibration.
measOutput float64 The voltage measured at the output of the module.

Return Value

Name Type Description
status int32 The error code returned by the function in the event of an error or warning. A value of 0 indicates success. A positive value indicates a warning. A negative value indicates an error.