Asmc Macro Assembler Reference
ASMC Nonfatal Error A2011
distance invalid for word size of current segment
A procedure definition or a code label defined with LABEL specified an address size that was incompatible with the current segment size. One of the following occurred:
- A NEAR16 or FAR16 procedure was defined in a 32-bit segment.
- A NEAR32 or FAR32 procedure was defined in a 16-bit segment.
- A code label defined with LABEL specified FAR16 or NEAR16 in a 32-bit segment.
- A code label defined with LABEL specified FAR32 or NEAR32 in a 16-bit segment.